ZB-8150/ZB-8110/ZB-8210CCD BARCODE SCANNERUser’s ManualZBA Inc 94 Old Camplain Road Hillsborough NJ 08844Phone: 908-359-2070 Fax: 908-359-1272
Keyboard wedge As a keyboard interface, the scanner supports most of the popular PCs and IBM terminals. The installation of the wedge is a fairly sim
Keyboard wedge Keyboard Layout: The selecting of keyboard layout supports many country languages other than USA keyboard layout. First you need to co
Keyboard layout USA Belgium Danish France Germany Italian Portuguese Spanish Swedish Switzerland UK Latin American 00* 01 02 03 04 05 06 07 08 09 10 1
Keyboard wedge Caps Lock: By selecting Caps Lock or No Caps Lock, scanner can get Caps Lock status. Power-on simulation: All of the PCs check the k
Program Option Bar Code Option Alphanumeric Entry Caps lock Caps lock”ON” Caps lock”OFF”00 01* Power-on simulationDisable Enable 00* 01 Inter-ch
RS-232 CTS: Clear To Send (Hardware Signal) RTS: Request To Send (Hardware Signal) Xon: Transmit On (ASCII Code 1116) Xoff: Transmit Off (ASCII Code
Program Option Bar Code Option Alphanumeric Entry Flow control None RTS/CTS Xon/Xoff ACK/NAK 00* 01 02 03 Inter-character delay00-99 (msec) 00-9
Program Option Bar Code Option Alphanumeric Entry Baud rate 300 BPS 600 BPS 1200 BPS 2400 BPS 4800 BPS 9600 BPS 19200 BPS 38400 BPS 00 01 02 03
Wand Emulation Bar/space polarity: High/low- Black will be transmitted as a high voltage level (+5) and space as low level (0V). Low/high- Black
Wand Emulation Output speed: This setting is same as serial transmission baud rate, and it must be approbated your wand decode resolution. The unit o
Installation:Keyboard Wedge 1) Turn off the PC2) Disconnect the keyboard cable from the PC. 3) Connect the Keyboard Cable to the scanner and connec
Reserved 00* Reserved 00* Margin delay 00-99 (10 pixel)00-99 15* Transmit delay 00-99 (10 msec)00-99 30* Exit 20
Scan Scanning mode: Good-read off-The trigger button must be pressed to activate scanning. The light source of scanner stops scanning when there i
Program Option Bar Code Option Alphanumeric Entry Scanning mode Good-read off Momentary Alternate Timeout off Continue 00 01* 02 03 04 Stand-
Scan Multi field scan: The scanner can be read many sets of barcode data on the same scanning line at the same time, even if they are different kinds
Multi field scan Disable Enable 00* 01 Global min. code length00-63 00-63 04* Global max.code length00-63 04-63 63* Inverted image scan Disable
Indication Power on alert: After power-on the scanner it will generate an alert signal to indicate a successful self-test. LED indication: After e
Program Option Bar Code Option Alphanumeric Entry Power on alert Disable Enable 00 01* LED indication Disable Enable 00 01* Buzzer indication
UPCA Read: Format Leading Zero Data Digits(11 Digits)Check Digit Check-sum transmission: By setting Enable, checks sum will be transmitted. Truncate
Check-sum verification Disable Enable 00 01* Check-sum transmissionDisable Enable 00 01* Max.code length 00-64 00-64 64* Min.code length 00-64 00-
UPCA Supplement digits: The Supplement digits barcode is the supplemental 2 or 5 characters for
Default Setting for each barcode shown as below: Read Enable Code Type 8110 8150/8210ChecksumVerification Enable ChecksumTransmissionEnable CodeIDUP
UPCE Read: Format Leading Zero Data Digits (6 Digits) Check Digits Check-sum verification: The checksum of EAN-13 is optional and made as the sum of
UPCE Truncate leading/ending: Refer to Truncate leading/ending of UPCA. Code Id setting: Refer to Code ID setting of UPCA. Insertion group selectio
Truncate ending 0-15 00-15 00* Code ID setting 00-ffH ASCII code 00-ffH < E >* Insert group selection 00-44 00-44 00* Supplement digits None
EAN-13 Read: Format Data Digits (12 Digits) Check Digits Check-sum verification: The checksum of EAN-13 is optional and made as the sum of the numeri
Check-sum verification Disable Enable 00 01* Check-sum transmission Disable Enable 00 01* Max.code length 00-64 00-64 64* Min.code length 00-64 00-6
EAN-13 Code Id setting: Refer to Code ID setting of UPCA. Insertion group selection: Refer to Insertion group selection of UPCA. Supplement digits
Program Option Bar Code Option Alphanumeric Entry Code ID setting 00-ffH ASCII code 00-ffH < F >* Insert group selection 00-44 00-44 00*
EAN-8 Read: Format Data Digits (7 Digits) Check Digits Check-sum verification: The checksum of EAN-8 is optional and made as the sum of the numerical
Check-sum transmission Disable Enable 00 01* Max.code length 00-64 00-64 64* Min.code length 00-64 00-64 01* Truncate leading 0-15 00-15 00* Trunca
EAN-8 Supplement digits: Format Data Digits(7 Digits)Check Digits Supplement Digits2 or 5 or UCC/EAN 128 Truncate Leading zero: Refer to Truncate Lea
ZBA ZB- 8110 / 8150 - 1D Barcode scannerSpecification Model 8110 Model 8150 Operational Light Source 660 nm Visible Red LED Optical System 2048 pi
Code 39 Read: Format Start“★” Data Digits( Variable)Checksum(Optional)End“★”Check-sum verification: The checksum of Code-39 is optional and made as
Code 39 Max./Min. code length: Each symbology has own Max./Min. Code Length. They can be set to qualify data entry. If their Max./Min. Code Length is
Max. code length 00-64 00-64 00* Min. code length 00-64 00-64 00* Truncate leading 0-15 00-15 00* Truncate ending 0-15 00-15 00* Code ID setting
Code 39 Append: This function allows several symbols to be concatenates and be treat as one single data entry. The scanner will not transmit the embe
Interleaved 2 of 5 Read: Format Data Digits (Variable) Checksum (Optional) Check-sum verification: The checksum is made as the sum module 10 of the
Interleaved 2 of 5 Max./Min. code length: Refer to Max./Min. code length of Code-39. Truncate leading/ending: Refer to Truncate leading/ending of UP
Code ID setting 00-ffH ASCII code 00-ffH < i >* Insert group selection 00-44 00-44 00* Exit 46
Industrial 2 of 5 Read: Format Data Digits (Variable) Checksum (Optional) Max./Min. code length: Refer to Max./Min. code length of Code-39. Truncat
Truncate leading 0-15 00-15 00* Truncate ending 0-15 00-15 00* Code ID setting 00-ffH ASCII code 00-ffH < i >* Insert group selection 00-44
Matrix 2 of 5 Eur Read: Format Data Digits (Variable) Checksum (Optional) Checksum Verification: The checksum is made as the sum module 10 of the n
Weight 155 g (cable not included) 160 g (cable not included) Cable – K/B wedge Straight 2.0 m Cable – universal type Straight 2.3 m Connector type R
Checksum Transmission Disable Enable 00* 01 Max. code length 00-64 00-64 00* Min. code length 00-64 00-64 00* Truncate leading 0-15 00-
Codabar Read: Format Start Data Digits (Variable) Checksum (Optional) End Checksum Verification: The checksum is made as the sum module 16 of the nu
Checksum Transmission Disable Enable 00* 01 Max. code length 00-64 00-64 00* Min. code length 00-64 00-64 00* Truncate leading 0-15 00-15 00* T
Codabar Insertion group selection: Refer to Insertion group selection of UPCA. Start/End type: The Codabar has four pairs of Start/End pattern; you m
Code-128 Read: Format Data Digits (Variable) Checksum (Optional) Checksum Verification: The checksum is made as the sum module 103 of all data dig
Code-128 Max./Min. code length: Refer to Max./Min. code length of Code-39. Truncate leading/ending: Refer to Truncate leading/ending of UPCA. Code Id
Truncate leading 0-15 00-15 00* Truncate ending 0-15 00-15 00* Code ID setting 00-ffH ASCII code 00-ffH < # >* Insert group selection
Code-93 Read: Format Data Digits(Variable)Checksum1(Optional)Checksum2(Optional)Checksum Verification: The checksum is made as the sum module 47 of
Checksum Transmission Disable Enable 00* 01 Max. code length 00-64 00-64 00* Min. code length 00-64 00-64 00* Truncate leading 0-15 00-15 00
Code-11 Read: Format Data Digits(Variable)Checksum1(Optional)Checksum2(Optional)Checksum Verification: The checksum is presented as the sum module
Programming Programming method Manual (Reading special barcode) DOS command through RS-232, Windows configuration program Program upgrade Enabled by
Checksum Transmission Disable Enable 00* 01 Max. code length 00-64 00-64 00* Min. code length 00-64 00-64 00* Truncate leading 0-15 00-15 00* T
MSI/plessey Read: Format Data Digits(Variable)Checksum1(Optional)Checksum2(Optional)Checksum Verification: The MSI/Plessey has one or two optional c
Checksum Transmission Disable Enable 00* 01 Max. code length 00-64 00-64 00* Min. code length 00-64 00-64 00* Truncate leading 0-15 00-15 00* T
UK/plessey Read: Format Data Digits (Variable) Checksum1+2(Optional) Checksum Verification: The UK/Plessey has one or two optional checksum digits.
Checksum Transmission Disable Enable 00* 01 Max. code length 00-64 00-64 00* Min. code length 00-64 00-64 00* Truncate leading 0-15 00-15 00* T
Telepen Read: IATA (International Air Transport Association). Checksum Verification: The checksum is presented as the sum module 10 or 11 of the data
Max. code length 00-64 00-64 00* Min. code length 00-64 00-64 00* Truncate leading 0-15 00-15 00* Truncate ending 0-15 00-15 00* Code ID setti
Standard 2 of 5 Read: Format Data Digits (Variable) Checksum1(Optional) Max./Min. code length: Refer to Max./Min. code length of Code-39. Truncat
Truncate leading 0-15 00-15 00* Truncate ending 0-15 00-15 00* Code ID setting 00-ffH ASCII code 00-ffH < i >* Insert group selection 00
RSS-14 Read: Format Data Digits (Variable) Checksum1(Optional) Max./Min. code length: Refer to Max./Min. code length of Code-39. Truncate leading/e
Programming the 8110/8150/8210 To program the 8110/8150/8210, you must scan a series of programming barcode in the correct order. Fold out the back c
Truncate leading 0-15 00-15 00* Truncate ending 0-15 00-15 00* Code ID setting 00-ffH ASCII code 00-ffH < R4 >* Insert group selection 0
RSS-Limited Read: Format Data Digits (Variable) Checksum1(Optional) Max./Min. code length: Refer to Max./Min. code length of Code-39. Truncate le
Min. code length 00-64 00-64 01* Truncate leading 0-15 00-15 00* Truncate ending 0-15 00-15 00* Code ID setting 00-ffH ASCII code 00-ffH <
RSS-Expanded Read: Format Data Digits (Variable) Checksum1(Optional) Max./Min. code length: Refer to Max./Min. code length of Code-39. Truncate l
Min. code length 00-64 00-99 01* Truncate leading 0-15 00-15 00* Truncate ending 0-15 00-15 00* Code ID setting 00-ffH ASCII code 00-ffH <
China Post Read: Format Data Digits (Variable) Checksum1(Optional) Max./Min. code length: Refer to Max./Min. code length of Code-39. Truncate lea
Truncate leading 0-15 00-15 00* Truncate ending 0-15 00-15 00* Code ID setting 00-ffH ASCII code 00-ffH < t >* Insert group selec
Italian Pharmacode Read: Format Data Digits (Variable) Checksum1(Optional) Max./Min. code length: Refer to Max./Min. code length of Code-39. Trun
Min. code length 00-64 00-64 09* Truncate leading 0-15 00-15 00* Truncate ending 0-15 00-15 00* Code ID setting 00-ffH ASCII code 0
Code-16K Only the ZB-8210 can decode Code-16K. Truncate leading/ending: Refer to Truncate leading/ending of UPCA. Code Id setting: Refer to Code ID se
Option Bar Code Option Alphanumeric Entry Interface selection Keyboard Wedge RS-232 Wand emulation USB Keyboard/RS-232 Auto detection reser
PDF-417 Only the ZB-8210 can decode PDF-417. Truncate leading/ending: Refer to Truncate leading/ending of UPCA. Code Id setting: Refer to Code ID sett
String setting Prefix characters: Up to 22 ASCII characters may be sent before data digits. Prefix Data Digits Suffix Suffix characters: Up to 22 ASCI
Preamble characters setting None 1-22 characters00* 00-ffH ASCII code Postamble characters setting None 1-22 characters00* 00-ffH ASCII code Insert G1
String setting Insert G1/G2/G3/G4 character setting: The scanner offer 4 positions and 4 characters to insert among the symbol. Example: Barcode “1 2
Insert G3 characters setting None 1-22 characters00* 00-ffH ASCII code Insert G4 characters setting None 1-22 characters00* 00-ffH ASCII code Exit
Transmission Preamble transmission: By setting Enable, Preamble will be appended before the data transmitted. Postamble transmission: By setting
Insert data group 1 position 00-64 (00: no insertion)00-64 00* Insert data group 2 position 00-64 (00: no insertion)00-64 00* Insert data group 3 pos
Transmission Code ID transmission: If your application is needed to transmit Code ID, you must set this to Proprietary ID or AIM ID. Code length tra
Code length transmission Disable Enable 00* 01 Code name transmission Disable Enable 00* 01 Case conversion Disable Upper case Lower case *For barcod
Test Chart CODABAR-PARA CODE-11 PARA CODE-128 PARA CODE-39 PARA CODE-93 PARA EAN-13 PARA 89
Interface Selection This decoder build-in scanner comes in one model and supports interfaces such as keyboard wedge, RS232 serial wedge, wand emulati
PDF-417 STANDRAD-25 PARA CODE-16K EAN-8 PARA INDUSTRIAL-25 PARA UPCE PARA 8754990
INTERLEAVED-25 PARA MATRIX 25 PARA MSI/PLESSEY PARA UPCA PARA UK/PLESSEY PARA 91
ASCII Code Table Note: For keyboard wedge only. L H 0 1 0 1 0 Null NUL DLE 1 Up F1 SOH DC1 2 Down F2 STX DC2 3 Left F3
Parameter Setting List Program Barcode standard parameter setting list If you wish to display the current configuration of your ZB-8110/8150/82
Firmware version list If you wish to display the firmware version, scan the Firmware version list. WARNING: Default value initialization If you
97 0A1B2C3D4E5F678Finish995